News

Home / News / What Factors Need To Be Considered When Specifying A Current Transformer?

What Factors Need To Be Considered When Specifying A Current Transformer?

There are many factors to consider when specifying a current transformer, which can make the process seem difficult or challenging. Below, we highlight some key factors to keep in mind to better understand the design process.

Turns ratio

Triad-CST25-Left-High Resolution
The turns ratio (also known as the conversion ratio) is the ratio of the number of turns in the secondary winding to the number of turns in the primary winding and vice versa. This ratio is the same as the voltage ratio. For example, if the turns ratio is 1:2 (secondary to primary), the voltage in the secondary winding will be 1 volt and the voltage in the primary winding will be 2 volts.

The turn ratio also affects two other aspects of transformer design. It sets the voltage across the load resistor (if present) and the magnetic flux density across the transformer.

Excitation current

Exciting current is the amount of current required to create and maintain a magnetic field within the transformer core. When voltage is applied to the terminals of the transformer and the secondary circuit is open, current flows into the primary.

Core

The cores of current transformers can be made from a variety of laminated or sintered materials. Each material exhibits different properties that make it suitable for different current sensing and switching applications. The two most commonly used are powder (ferrite) materials (for high-frequency applications) and nanocrystalline materials (for low-frequency applications).

temperature

The temperature of the core material affects its resistance, which in turn affects the output of the transformer. Therefore, before selecting a material for a transformer design, it is important to consider how the expected operating and ambient temperatures in the application will affect the potential core material.

The output voltage

The output voltage of the current transformer refers to the voltage value after the switching operation. It should be set as low as possible to minimize insertion loss.

Load Resistance

Load resistors protect the current transformers under open circuit conditions. They allow high voltages to be applied across them, allowing current to flow through them and preventing voltage from damaging the insulation. Both accuracy and temperature behavior are important considerations when selecting a load resistor for a transformer.

Recommended Products